The new range of Full DC Inverter modular heat pumps is ideal for cooling and heating residential and commercial buildings. Available in two sizes, with 35 and 60 kW cooling capacity, one of its most important advantages is its modularity; in fact, it is possible to combine the two models up to 16 units, for a maximum of 960 kW of power.
Additional information
| Power ratings | 36,02 62,60 kW (three-phase) |
|---|---|
| Scope | Residential, Commercial |
| Application | Condominium, Hotel, Shopping centre, SPA, Gyms |
| Solutions | Cooling, Heating, Domestic hot water, Cooling + Heating + DHW, Heating + DHW |
| System | A2W heat pump |
| Installation | Monoblock, Outdoor unit |
| Refrigerant | R32 |
A++
Energy efficiency in heating mode with 35°C flow water temperature
960 kW
Maximum power when combining 16 60 kW units
52dB(A)
Noise level at partial loads
Modbus
The system is equipped with Modbus protocol as standard

-15°C / 52°C
Minimum external temperature in cooling mode

-20°C / 40°C
Minimum outdoor temperature in heating mode
Frost protection for temperatures below 5°C
Frost protection is automatically activated by the unit when the external temperature falls below 5°C, in both cooling and heating modes.
Centralised control of up to 16 units
The wired control allows you to control up to 16 units.
- It is equipped with a 4.3-inch backlit liquid crystal touch screen display.
- It allows you to view parameters and operating status in real time.
- It features an anti-corrosion structure.
- The touch screen allows for quick and easy operation.
- It can display up to 10 error codes on the same page.

MW MODULAR MONOBLOCK R32, MAXIMUM ENERGY EFFICIENCY, SIGNIFICANT REDUCTION IN CONSUMPTION
SILENT MODE
- Large plastic fan blades
- Quiet mode function
- Compressor sound insulation
- Special fan area design
Longer service life with balanced operation function
Thanks to smart control, it is possible to balance the operating time of the compressors in order to avoid overloading just a few of them, which improves the reliability of the system and its service life.
Energy consumption control with “Energy saving” mode
The unit is able to estimate the thermal load of the building based on the outside air temperature, adjusting the flow water temperature setting accordingly in order to reduce energy consumption.
High efficiency with tube bundle heat exchanger
Dual flow design heat exchanger to increase the efficiency and capacity of the unit. The special design of the plate and the related throttles at the heat exchanger inlet maintain a regular and uniform refrigerant flow in order to improve exchange efficiency. The U-shaped threading inside the copper pipes improves the laminar flow of the fluid and facilitates heat exchange.
Anti-freeze protection for temperatures below 5°C
Frost protection is automatically activated by the unit when the outside temperature drops below 5°C, both in cooling and heating modes.
Greater reliability with the hydronic pump rotation function
The units do not have hydronic pumps, which must therefore be provided externally, even in pairs. The pump rotation function can be activated automatically in order to increase their service life.
Comfort in winter with selective machine defrosting
Only one third of the outdoor units are allowed to defrost at the same time, thus reducing fluctuations in the outlet water temperature and, consequently, improving room comfort.